Assessment of a membrane drinking water filter in an emergency setting
This study evaluated the performance and acceptability of the Nerox membrane drinking water filter among internally displaced people in Pakistan. The membrane filter and a ceramic candle filter (as a control) were distributed to over 3,000 households.
Six months later, 230 households were visited. Only 6% still had a working filter, and removal performance ranged from 80% to 93%. High turbidity in the source water (irrigation canals), high temperatures and large family sizes probably contributed to poor performance and uptake.
Ensink, Bastable and Cairncross. Journal of Water and Health, 13(2), 2015.
Assessment of a membrane drinking water filter in an emergency setting
This study evaluated the performance and acceptability of the Nerox membrane drinking water filter among internally displaced people in Pakistan. The membrane filter and a ceramic candle filter (as a control) were distributed to over 3,000 households.
Six months later, 230 households were visited. Only 6% still had a working filter, and removal performance ranged from 80% to 93%. High turbidity in the source water (irrigation canals), high temperatures and large family sizes probably contributed to poor performance and uptake.
Ensink, Bastable and Cairncross. Journal of Water and Health, 13(2), 2015.